The superior performance of the bag filter itself is not difficult to maintain. Daily work is to check whether the chimney is emitting smoke. If smoke is emitted, it indicates that the bag of the dust collector is damaged and should be replaced in a timely manner. If there is no smoke, it indicates that the dust collector bag is not damaged. Due to the advantages of easy maintenance such as the oil filling hole of the fan, it is widely used. Actual investigations and statistical materials show that if the normal operation and management of the bag filter are not valued, even the best equipment cannot fully exert its performance, and various types of faults may even occur, making it difficult to maintain. However, if maintenance and operation personnel are experienced and responsible, even if there are some defects in design and manufacturing, under normal operating and maintenance conditions, The equipment may also run for a long time and have lower operating costs. It can be seen that the maintenance and management of bag filters cannot be an optional issue, but a very important and important one that must be taken seriously.
Key points for dust collector maintenance
1) It is necessary to establish a dust removal system and regularly remove dust
2) When handling high-temperature gases, condensation caused by cooling should be prevented
3) Dust discharge outlets and inspection doors should be securely sealed
4) Properly managing equipment accessories
5) Regularly replace filter bags based on usage and filter bag material
source
1) Pay attention to the start-up of the fan (the fuse is easily blown during start-up to avoid the motor burning out due to single machine operation)
2) Electrical switches with relays must be used
3) Strictly follow the electrical wiring methods specified by the manufacturer
4) The staff responsible for managing power switches should be relatively stable
Other maintenance
1) Outdoor areas should be painted with anti rust paint every 1-2 years
2) When there is water, it should be prevented from freezing
3) The vacuum hood that draws in flammable gases should be hung with a “No Smoking” sign
4) To prevent sparks from grinding operations from entering the dust removal system, corresponding measures should be taken
5) Explosion prevention measures should be taken for flammable dust
6) Large dust removal systems should have anti-static measures
pipeline
1) Pay attention to the detachment, corrosion, and perforation of pipeline connections
2) We cannot add branches casually
3) Pay attention to the firmness of the bracket
4) Regularly inspect the pipeline for dust accumulation
Contact Person: Miss. Doreen Zou
Tel: 0086 135 8806 5995
Fax: 86-571-86073956